ICC-ES Certified Flood Vents

Can't find our ICC-ES Products?

Explore FloodGuard Vents

Our Crawl Space Door Systems propriety ICC-ES collection has permanently moved to FloodGuard Vents - or you can shop our Flood Flaps collection below.

4 products

Color
Color
Color

What You Need to Know

ICC-ES certified flood vents provide engineered flood protection that meets National Flood Insurance Program requirements while potentially reducing flood insurance premiums. These engineered openings allow automatic floodwater entry and exit to equalize hydrostatic pressure on foundation walls during floods—preventing structural damage while satisfying NFIP compliance for enclosed areas below base flood elevation. If these styles don't fit your application, explore FloodGuard Vents for more options. 

Why ICC-ES Certification Matters

Engineered flood vents differ fundamentally from non-engineered (prescriptive) flood vents. ICC-ES certification from the International Code Council Evaluation Service means these products have been tested and verified to meet the performance standards required by federal flood regulations. Local building officials and insurance providers recognize ICC-ES certification, making these vents acceptable for NFIP compliance nationwide. This certification is essential for flood insurance premium reductions and building code compliance in flood-prone areas.

Flood Insurance Premium Reduction

Installing ICC-ES certified flood vents can significantly lower flood insurance costs through the National Flood Insurance Program. By allowing automatic floodwater entry and exit, these vents equalize pressure on foundation walls, reducing structural damage risk. Lower risk translates directly to reduced premiums. Premium reductions vary based on base flood elevation, structure elevation, flood zone designation, and geographic location—contact your flood insurance provider with ICC-ES documentation to request premium re-evaluation after installation.

Engineered vs. Non-Engineered Flood Vents

Non-engineered flood vents simply provide openings that meet minimum size requirements (1 square inch per square foot of enclosed area). Engineered flood vents are designed, tested, and certified to perform under actual flood conditions. They may include screens, louvers, valves, or coverings—as long as they permit automatic floodwater entry and exit. ICC-ES certification validates this performance, providing the documentation required by insurance providers and building officials.

Multiple Configurations Available

Our ICC-ES certified flood vent collection includes options for different applications: multi-purpose vents with air circulation for traditional crawl spaces, sealed vents for encapsulated crawl spaces, and low-profile overhead door vents for garages. All provide 220 square feet of coverage per vent—competitive coverage that reduces the number of vents required compared to many alternatives, lowering installation costs while maintaining full NFIP compliance. 

Important Note on FEMA Terminology

Federal policy prohibits FEMA from approving, endorsing, certifying, or recommending any products. While our flood vents comply with FEMA design guidance and NFIP requirements, terms like "FEMA approved" or "FEMA certified" are incorrect. The proper terminology is "ICC-ES certified engineered opening that meets NFIP requirements."

Frequently Asked Questions

The distinction determines NFIP compliance and insurance eligibility.

Non-Engineered (Prescriptive) Flood Vents:

  • Simple openings meeting minimum size (1 sq in per sq ft of enclosed area)
  • No certification required
  • Must be completely open (no screens, louvers, or coverings)
  • Limited to basic foundation wall installations
  • No performance testing or validation

Engineered Flood Vents:

  • Designed and tested to meet specific performance standards
  • ICC-ES certification validates compliance with federal regulations
  • May include screens, louvers, or coverings while maintaining automatic operation
  • Accepted by local officials and insurance providers nationwide
  • Covers more area per vent (our vents: 220 sq ft each vs. 150 sq ft typical for prescriptive)

Why Engineered Matters:

  • Insurance providers require documentation for premium reductions
  • ICC-ES certification provides that documentation
  • Building officials accept certified products without additional engineering
  • Greater flexibility in application and installation

Bottom Line: Engineered vents with ICC-ES certification provide verified performance and official documentation required for flood insurance benefits.

Calculate based on enclosed area square footage below base flood elevation.

Calculation:

  1. Measure total square footage of enclosed area
  2. Divide by the coverage per vent
  3. Round UP to nearest whole number
  4. Minimum of 2 vents required on opposing walls

Examples:

  • 880 sq ft crawl space: 880 ÷ 220 = 4 vents minimum
  • 1,320 sq ft garage: 1,320 ÷ 220 = 6 vents minimum
  • 550 sq ft enclosed area: 550 ÷ 220 = 2.5, round to 3 vents

Distribution Requirements:

  • Place vents on at least two opposing foundation walls
  • Distribute evenly around perimeter for balanced pressure equalization
  • Position no more than 12 inches above adjacent grade
  • Space at least 3 feet apart for effective water flow

Why Opposing Walls Matter: Floodwater must flow both IN and OUT freely. Vents on one wall only create bottleneck that prevents proper pressure equalization.

Choose based on your crawl space ventilation strategy.

Multi-Purpose Flood Vents (with Air Circulation):

  • 37 sq in continuous ventilation through louvers during normal conditions
  • Automatic flood protection when needed
  • Best for: Traditional vented crawl spaces with open foundation vents
  • Provides both moisture control and flood compliance
  • Maintains airflow year-round

Sealed Flood Vents (No Air Circulation):

  • Solid construction with no ventilation during normal conditions
  • Automatic flood protection when needed
  • Best for: Encapsulated crawl spaces with vapor barriers and dehumidifiers
  • Maintains sealed environment while meeting flood requirements
  • Prevents humid outdoor air infiltration

Key Decision Factor: If you have a vapor barrier and dehumidifier (encapsulated), use sealed vents. If you rely on traditional ventilation through foundation vents, use multi-purpose vents.

Both Types: ICC-ES certified, 220 sq ft coverage, automatic operation, available in black/white/gray.

Yes, but premium reduction varies based on multiple factors.

How Flood Vents Reduce Premiums:

  • Allow automatic floodwater entry and exit
  • Equalize hydrostatic pressure on foundation walls
  • Prevent structural damage from trapped water pressure
  • Reduced damage risk = lower insurance premiums

Factors Affecting Your Reduction:

  • Base flood elevation vs. your structure elevation
  • Number of feet below base flood elevation
  • Flood zone designation (A, AE, VE, X, etc.)
  • Current policy coverage levels
  • Geographic location and flood history

To Get Premium Reduction:

  1. Install ICC-ES certified flood vents meeting NFIP requirements
  2. Ensure installation meets local building codes
  3. Obtain documentation (ICC-ES certificate, installation photos)
  4. Contact flood insurance provider to request premium re-evaluation
  5. Submit certification documentation

Typical Savings: Vary widely from hundreds to thousands annually depending on risk reduction achieved. Contact your insurance provider for estimate based on your specific property.

Important: ICC-ES certification is essential—insurance providers require certified products for premium reductions.